As previously demonstrated, an excellent timing resolution below 100 ps FWHM is possible in time-of-flight positron emission tomography (TOF PET) if the detection method is based on the principle of detecting photons of Cherenkov light, produced in a suitable material and detected by microchannel plate photomultipliers (MCP PMTs). In this work, the silicon photomultipliers (SiPMs) were tested for the first time as the photodetectors in Cherenkov TOF PET. The high photon detection efficiency (PDE) of SiPMs led to a large improvement in detection efficiency. On the other hand, the time response of currently available SiPMs is not as good as that of MCP PMTs. The SiPM dark counts introduce a new source of random coincidences in Cherenkov method, which would be overwhelming with present SiPM technology at room temperature. When the apparatus was cooled, its performance significantly improved.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2015.09.059Additional details
Identifiers
- DOI
- 10.1016/j.nima.2015.09.059;
- PII
- S0168-9002(15)01114-6;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 804
- Journal Page Range
- p. 127-131
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48005827
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CHERENKOV RADIATION; EFFICIENCY; LEAD FLUORIDES; MICROCHANNEL ELECTRON MULTIPLIERS; PERFORMANCE; PHOTODETECTORS; PHOTOMULTIPLIERS; PHOTONS; POSITRON COMPUTED TOMOGRAPHY; RADIATION DETECTION; RESOLUTION; TEMPERATURE RANGE 0273-0400 K; TIME-OF-FLIGHT METHOD
- Descriptors DEC
- BOSONS; COMPUTERIZED TOMOGRAPHY; DETECTION; DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; ELECTRON MULTIPLIERS; ELECTRON TUBES; ELEMENTARY PARTICLES; EMISSION COMPUTED TOMOGRAPHY; FLUORIDES; FLUORINE COMPOUNDS; HALIDES; HALOGEN COMPOUNDS; LEAD COMPOUNDS; LEAD HALIDES; MASSLESS PARTICLES; PHOTOTUBES; RADIATIONS; TEMPERATURE RANGE; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.