Published 1981 | Version v1
Book

The calibration of silicon carbide temperature monitors in a fast reactor

Creators

  • 1. UKAEA Dounreay Nuclear Power Development Establishment

Description

Silicon carbide pellets have been used as the standard temperature monitor in uninstrumented rigs in the Dounreay Fast Reactor for 10 years. The irradiation-induced expansion of the β-silicon carbide was plotted as a function of its post-irradiation anneal temperature, and the temperature at which recovery of the expansion began to take place was taken to be the irradiation temperature. Some recent research, however, suggested that silicon carbide monitor results might not exactly correspond to the actual irradiation temperatures as measured by thermocouples. In the present work, 22 silicon carbide monitors were irradiated against thermocouples in the Dounreay Fast Reactor across the temperature range 4250 to 5750C. The monitor results were directly proportional to the corresponding thermocouple readings, but with a constant silicon carbide 'hot bias' of approximately 20 deg C. Using the derived correlation equation, equivalent thermocouple temperatures can be calculated from future monitor results; the 95% confidence limits on an irradiation temperature calculated from the mean result of a group of 3 identically irradiated monitors is +- 20 to 25 deg C. (author)

Additional details

Publishing Information

Publisher
British Nuclear Energy Society.
Imprint Place
London
ISBN
0 7277 0111 8
Imprint Title
Post-irradiation examination
Imprint Pagination
366 p.
Journal Page Range
p. 87-90.

Conference

Title
British Nuclear Energy Society conference.
Dates
13 - 16 May 1980.
Place
Grange-over-Sands, UK.