Published January 2013 | Version v1
Journal article

Accurate estimation of dose distributions inside an eye irradiated with 106Ru plaques

  • 1. Universitaetsklinikum Essen (Germany). NCTeam, Strahlenklinik
  • 2. Universitat Politecnica de Catalunya, Barcelona (Spain). Inst. de Tecniques Energetiques
  • 3. Marburg Univ. (Germany). Klinik fuer Strahlentherapie und Radioonkologie

Description

Background: Irradiation of intraocular tumors requires dedicated techniques, such as brachytherapy with 106Ru plaques. The currently available treatment planning system relies on the assumption that the eye is a homogeneous water sphere and on simplified radiation transport physics. However, accurate dose distributions and their assessment demand better models for both the eye and the physics. Methods: The Monte Carlo code PENELOPE, conveniently adapted to simulate the beta decay of 106Ru over 106Rh into 106Pd, was used to simulate radiation transport based on a computerized tomography scan of a patient's eye. A detailed geometrical description of two plaques (models CCA and CCB) from the manufacturer BEBIG was embedded in the computerized tomography scan. Results: The simulations were firstly validated by comparison with experimental results in a water phantom. Dose maps were computed for three plaque locations on the eyeball. From these maps, isodose curves and cumulative dose-volume histograms in the eye and for the structures at risk were assessed. For example, it was observed that a 4-mm anterior displacement with respect to a posterior placement of a CCA plaque for treating a posterior tumor would reduce from 40 to 0% the volume of the optic disc receiving more than 80 Gy. Such a small difference in anatomical position leads to a change in the dose that is crucial for side effects, especially with respect to visual acuity. The radiation oncologist has to bring these large changes in absorbed dose in the structures at risk to the attention of the surgeon, especially when the plaque has to be positioned close to relevant tissues. Conclusion: The detailed geometry of an eye plaque in computerized and segmented tomography of a realistic patient phantom was simulated accurately. Dose-volume histograms for relevant anatomical structures of the eye and the orbit were obtained with unprecedented accuracy. This represents an important step toward an optimized brachytherapy treatment of ocular tumors. (orig.)

Additional details

Publishing Information

Journal Title
Strahlentherapie und Onkologie
Journal Volume
189
Journal Issue
1
Journal Page Range
p. 68-73
ISSN
0179-7158
CODEN
STONE4