Published 1995 | Version v1
Book

High temperature pH measurements

  • 1. Bhabha Atomic Research Centre, Kalpakkam (India). Water and Steam Chemistry Lab.

Description

High temperature pH measurement in the primary and secondary coolant system of nuclear reactors on a continuous basis is gaining importance in recent years. High temperature pH measurements were carried out in a static autoclave using yttria stabilised zirconia (YSZ) probe as pH sensor and Ag/AgCl as internal reference electrode for boric acid and LiOH mixtures at temperatures between 423K and 523K. The precision of pHT measurements were found to be satisfactory though dilution of the filling solution of the internal electrode compartment contributed to the deviation in the pH measured when compared to the computed values. (author). 4 refs., 1 tab., 2 figs

Part of:
Proceedings of the symposium on current trends in water chemistry of nuclear and thermal power plants and other related units

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre.
Imprint Place
Bombay (India)
Imprint Title
Proceedings of the symposium on current trends in water chemistry of nuclear and thermal power plants and other related units
Imprint Pagination
330 p.
Journal Page Range
p. 274-276.

Conference

Title
current trends in water chemistry of nuclear and thermal power plants and other related units.
Acronym
CURTWAC-95
Dates
13-16 Feb 1995.
Place