Ultra low-dose of gadobenate dimeglumine for late gadolinium enhancement (LGE) imaging in acute myocardial infarction: A feasibility study
Creators
- 1. Department of Radiological Sciences, Pathology and Oncology, Policlinico Umberto I, "Sapienza" University of Rome, Viale Regina Elena 315, 00161 Rome (Italy)
- 2. Service de Radiologie et Imagerie Cardiovasculaire, Hôpital Cardiologique, Centre Hospitalier Régional et Universitaire de Lille, Avenue Oscar Lambret, 59037 Lille Cedex (France)
- 3. Department of Cardiovascular, Respiratory, Nephrologic, Anestesiologic and Geriatric Sciences, Sapienza University of Rome, Policlinico Umberto I, Via del Policlinico 165, 00161 Rome, Rome (Italy)
Description
Highlights: • We compared two gadolinium dose for late enhancement imaging in acute infarction. • We evaluated image quality both qualitatively and quantitatively. • Low dose regimen is feasible and provides better image quality at 5–10 min delay. • Standard dose warrants better image quality and should be routinely preferred. - Abstract: Purpose: To assess the feasibility of using an ultra-low dose (0.05 mmol/kg of body weight [BW]) of high relaxivity contrast agent for late gadolinium enhancement (LGE) imaging in patients with acute myocardial infarction (AMI). Materials and methods: 17 consecutive patients (mean age, 60.1 ± 10.3 years) with ST-segment elevation AMI underwent two randomized cardiac magnetic resonance studies (exam intervals between 24 and 48 h) on a 1.5 T unit during the first week after the event using gadobenate dimeglumine (Gd-BOPTA) at the dose of 0.1 mmol/kg BW (standard dose or SD group) and 0.05 mmol/kg BW (half dose or HD group). Image quality was qualitatively assessed. Quantitative analysis of LGE were performed by measuring signal intensity (SI), signal-to-noise ratio (SNR) in the infarcted myocardium (IM), non-infarcted myocardium (N-IM) and left ventricular cavity (LVC) in images acquired at 1, 3, 5, 10, 15 and 20 min after administration of Gd-BOPTA using both contrast media protocol. Contrast-to-noise ratio (CNR) between IM and N-IM (CNR IM/N-IM) and between IM and LVC (CNR IM/LVC) were also quantified for each time point. Moreover the extent of infarcted myocardium was measured. Results: 102 LGE images were evaluated for each dose group. Quality score was significantly higher for SD at 1, 15 and 20 min (0.002 < p < 0.046) and for HD at 5 min (p = 0.013). SNR has been higher in the SD group compared to the HD group even though not statistically significant at any time-point for both IM (SD vs. HD: 87.7 ± 73 vs. 65 ± 66; 0.15 < p < 0.38) and N-IM (SD vs. HD: 22 ± 61 vs. 9.9 ± 6.5; 0.09 < p < 0.43). LVC SNR was significantly higher with SD at 10 min (p = 0.03), 15 min (p = 0.001) and 20 min (p = 0.004). CNR between the IM and N-IM was significantly higher using SD compared to HD (1382.24 ± 1049 vs. 695.4 ± 500; 0.000 < p < 0.028) at 10, 15 and 20 min. No significant differences in CNR IM/LVC were noted for HD acquired 5 min after CM administration compared to SD acquired at 10 (p = 0.34), 15 (p = 0.96) and 20 (p = 0.41) min, and between HD at 10 min compared to SD acquired at 15 min (p = 0.78) and 20 min (p = 0.32). Good correlation between SD and HD (0.56 < r2 < 0.85, p < 0.024) was found at all time-points in the measuring of IA. Conclusion: The use of a 0.05 mmol/kg dose of gadobenate dimeglumine is feasible for LGE imaging of acute MI and the best image quality is obtained at 5 min after contrast administration. It could be beneficial in patient with renal failure and a solution to improve the identification of subendocardial infarction reducing examination time, costs and total gadolinium load. However, the standard dose of 0.1 mmol/kg provides overall better image quality, with the best performance obtained at the delay of 10 min or more after Gd-BOPTA administration, and it should be routinely preferred
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2014.09.002Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2014.09.002;
- PII
- S0720-048X(14)00430-6;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 83
- Journal Issue
- 12
- Journal Page Range
- p. 2151-2158
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47005428
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CHEST; COMPARATIVE EVALUATIONS; CONTRAST MEDIA; CORRELATIONS; FAILURES; FEASIBILITY STUDIES; GADOLINIUM; IMAGES; KIDNEYS; MYOCARDIAL INFARCTION; MYOCARDIUM; NMR IMAGING; NOISE; PATIENTS; SIGNAL-TO-NOISE RATIO
- Descriptors DEC
- BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DISEASES; ELEMENTS; EVALUATION; HEART; MEDICINE; METALS; MUSCLES; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RARE EARTHS
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.