Published October 2002
| Version v1
Journal article
18-months cycle reload design verifications of Daya Bay Nuclear Power Station
Creators
- 1. Nuclear Power Inst. of China, Chengdu (China)
- 2. Guangdong Nuclear Power Joint Venture Co. LTD., Shenzhen (China)
Description
18-Months cycle reload design verifications of Daya Bay NPS is briefly described. It was attempted giving the description of analysis scope and key technology for a nuclear power plant which will be changed fuel management strategy from one year to 18-months cycle
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 23
- Journal Issue
- 5
- Journal Page Range
- p. 1-4
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 34053618
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- DAYA BAY-1 REACTOR; DAYA BAY-2 REACTOR; DESIGN; FUEL MANAGEMENT; HEAT TRANSFER; HYDRAULICS; NUCLEAR POWER PLANTS; REACTOR ACCIDENTS; REACTOR CORES; REACTOR FUELING; SAFETY ANALYSIS; TECHNOLOGY ASSESSMENT
- Descriptors DEC
- ACCIDENTS; ENERGY TRANSFER; ENRICHED URANIUM REACTORS; FLUID MECHANICS; MANAGEMENT; MECHANICS; NUCLEAR FACILITIES; NUCLEAR MATERIALS MANAGEMENT; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTOR COMPONENTS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS