Published November 1, 1998 | Version v1
Report

Adaptive Readout Technique For A Sixteen Channel Peak Sensing ADC In the FERA Format

Description

An adaptive, variable block-size readout technique for use with multiple, sixteen-channel CAMAC ADCs with a FERA-bus readout has been developed and designed. It can be used to read data from experiments with or without coincidence, i.e. singles, without having to change the readout protocol. Details of the implementation are discussed and initial results are presented. Further applications of the adaptive readout are also discussed

Availability note (English)

Available from INIS in electronic form; Also available from OSTI as DE00008746; PURL: https://www.osti.gov/servlets/purl/8746-AnhnfE/webviewable/

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
LBNL--41718

Conference

Title
1998 IEEE Nuclear Science Symposium and Medical Imaging Conference
Dates
8-14 Nov 1998
Place
Toronto, ON (Canada)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
32065731
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CAMAC SYSTEM; DESIGN; IMPLEMENTATION; PERFORMANCE; READOUT SYSTEMS

Optional Information

Contract/Grant/Project number
AC03-76SF00098
Funding organization
USDOE Office of Science (United States)