Published December 2000 | Version v1
Journal article

Cascade test of removing Nd3+ and Am3+ from simulated high level liquid waste of nuclear power station

  • 1. Tsinghua Univ., Beijing (China). Inst. of Nuclear Energy Technology

Description

Using 10 stages for extraction, 2 stages for scrubbing, the code test was proceeded on the miniature centrifugal contactors with 10 mm diameter using Nd3+ to simulate Am3+. The results showed that the decontamination factor (DF) of Nd3+ reached 5 x 105. The concentration profiles of Nd3+, Fe3+, H+, etc and their material balances were given. The radioactive tracing test of Am3+ was carried out based on the cold test. The DF of Am3+ was 1.26 x 106. The results of the cold and tracing test showed that the non-α waste requirement of high level liquid waste of nuclear power station could be met by TRPO process

Additional details

Publishing Information

Journal Title
Journal of Tsinghua University. Science and Technology
Journal Volume
40
Journal Issue
12
Journal Page Range
p. 21-24
ISSN
1000-0054
CODEN
QDXKE8