There is a newer version of the record available.

Published August 1963 | Version v1
Journal article

The separation of 242Cm from JRR-1 neutron irradiated 241Am. Cation exchange with a-hydroxy isobutyrate

Creators

  • 1. Japan Atomic Energy Research Institute, Chemistry Div., Tokai, Ibaraki (Japan)

Description

242Cm was separated from JRR-1 irradiated 241Am. The separation was carried out at room temperature by the elution with 0.5 M ammonium α-hydroxy isobutyrate of pH 3.68 from the column of 8% cross linked Diaion SK♯1. The flow rate of 1 drop/5 min was found to give a good separation of 242Cm from 241Am. The separation factor was calculated to be 1.49. Radiochemical purity of curium fraction was checked by means of decay curve and α pulse height analyses. (author)

Additional details

Identifiers

Publishing Information

Journal Title
Nippon Genshiryoku Gakkai-Shi
Journal Volume
5
Journal Issue
8
Series
雑誌名:日本原子力学会誌
Journal Page Range
p. 640-643
ISSN
0004-7120

Optional Information

Notes
14 refs., 4 figs.