Published May 21, 2016 | Version v1
Journal article

The upgrade of the cold neutron three-axis spectrometer IN12 at the ILL

  • 1. Jülich Centre for Neutron Science JCNS, Forschungszentrum Jülich GmbH, Outstation at ILL, BP 156, 38042 Grenoble (France)
  • 2. Université Grenoble Alpes and CEA Grenoble, INAC MEM, 38054 Grenoble (France)
  • 3. Forschungszentrum Jülich, Peter Grünberg Institut PGI 6, D-52425 Jülich (Germany)
  • 4. Institut Laue-Langevin, 71 Avenue des Martyrs, 38042 Grenoble Cedex 9 (France)
  • 5. Jülich Centre for Neutron Science JCNS and Peter Grünberg Institut PGI, JARA-FIT, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany)

Description

After nearly 40 years of successful operation the cold three-axis spectrometer IN12 at the Institut Laue-Langevin, Grenoble, France, has been relocated to a new position and the primary spectrometer has been upgraded. Latest modern optical components are employed. A new guide in combination with a virtual source concept and a double focusing monochromator guarantee highest flux. With its high unpolarized and polarized neutron flux IN12 allows for demanding experiments. A velocity selector in the guide ensures a clean beam and a very low background. A gain in flux of about an order of magnitude at the sample position has been achieved compared to the previous instrument and IN12's wavelength range now extends far into the warmish region.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2016.02.067

Additional details

Identifiers

DOI
10.1016/j.nima.2016.02.067;
PII
S0168-9002(16)00243-6;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
819
Journal Page Range
p. 89-98
ISSN
0168-9002
CODEN
NIMAER

INIS

Optional Information

Copyright
Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.