This study tested the ability of first-pass radionuclide angiocardiography to detect accurately the left ventricular endocardial surface of the intact, conscious, chronically instrumented dog. A spherical phantom was used to define the influence of collimation. These were used to analyze cardioscintigrams obtained in 19 studies of six dogs. The dogs were provided with pulse transit sonomicrometer dimension transducers on the endocardium, right-atrial pacing electrodes, electrocardiographic leads, and catheters in the superior vena cava and right or left atria. The minor-axis dimension of the left ventricle was measured ultrasonically while the cardioscintigram was being stored. The minor-axis dimension and end-diastolic volume obtained by the two techniques had linear correlation coefficients of 0.95 and 0.98. This correlation indicates the inherent accuracy of radionuclide techniques by defining left-ventricular endocardial edges for a large range of volumes in the dog

Additional details

Additional titles

Augmented title (English)
Dogs; phantom

Publishing Information

Journal Title
J. Nucl. Med.
Journal Volume
22
Journal Issue
6
Series
J. Nucl. Med.
Journal Page Range
500-505
ISSN
0022-3123

Conference

Title
28. Society of Nuclear Medicine annual meeting.
Dates
16 Jun 1981.
Place