Published December 2016 | Version v1
Journal article

Analysis of X-ray spectra in 14.5-GHz ECR ion source for optimizing operation conditions

  • 1. Department of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of)
  • 2. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

An electron cyclotron resonance (ECR) ion source operating at 14.5 GHz was developed for the generation of charged ions at the Korea Atomic Energy Research Institute (KAERI). Experiments were carried out to study the plasma inside the ECR ion source by analyzing the X-ray spectra generated by it. The X-ray energy distribution and electron energy inside the plasma chamber are influenced by the status of the heated plasma. That status depends on various operation parameters such as microwave power, injected gas-pressure, and solenoid and trim coil currents. X-ray spectra were recorded to find the correlation between the plasma and the X-rays for variations in the operation parameters. A standard NaI(Tl) detector was used for that purpose. The X-ray energy distribution was studied in the range of 100–500 W for radiofrequency power. The influence of the injected gas pressure and the mirror ratio in the emission of X-rays were analyzed. (author)

Availability note (English)

Available from http://dx.doi.org/10.1080/00223131.2016.1195303

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo)
Journal Volume
53
Journal Issue
12
Journal Page Range
p. 2072-2078
ISSN
0022-3131

Optional Information

Notes
10 refs., 13 figs., 1 tab.