Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI
Creators
- 1. Graduate School of Medical Sciences, Kyushu University, Department of Clinical Radiology, Higashi-ku, Fukuoka (Japan)
- 2. Graduate School of Medical Sciences, Kyushu University, Department of Molecular Imaging and Diagnosis, Higashi-ku, Fukuoka (Japan)
- 3. Graduate School of Medical Sciences, Kyushu University, Department of Pediatrics, Higashi-ku, Fukuoka (Japan)
- 4. Graduate School of Medical Sciences, Kyushu University, Department of Cardiovascular Medicine, Higashi-ku, Fukuoka (Japan)
- 5. Graduate School of Medical Sciences, Kyushu University, Department of Cardiovascular Surgery, Higashi-ku, Fukuoka (Japan)
- 6. Graduate School of Medical Sciences, Kyushu University, Department of Health Sciences, Higashi-ku, Fukuoka (Japan)
Description
To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0 %) and PRF (-9.1 ± 2.0 %) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-014-3344-1Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 24
- Journal Issue
- 12
- Journal Page Range
- p. 3289-3299
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 46006937
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CORRELATIONS; HEART; LUNGS; MAGNETIC FIELDS; MILLI SV RANGE 01-10; NMR IMAGING; RADIATION DOSES; STATISTICS; SURGERY; VOMITING
- Descriptors DEC
- BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DOSES; EQUIVALENT DOSE RANGE; EVALUATION; MATHEMATICS; MEDICINE; MILLI SV RANGE; ORGANS; RADIATION DOSE RANGES; RESPIRATORY SYSTEM; SYMPTOMS; TOMOGRAPHY