Published 2007
| Version v1
Journal article
Preparation and quality control methods of radiopharmaceutical agents for isotope diagnostics and therapy using somatostatin derivatives
Creators
- 1. Zaklad Medycyny Nuklearnej i Endokrynologii Onkologicznej, Centrum Onkologii im. M. Sklodowskiej-Curie, Warsaw (Poland)
Description
The details of the quality control procedures of 99mTc- Tectrotyde, 99mTc -HYNIC-tyr3 Octreotyd and 111In Octreosan and 90Y are described. The main steps of preparation, quality control,and dosage after labelling are given
Additional details
Additional titles
- Original title (Polish)
- Metody przygotowania i kontroli jakosci radiofarmaceutykow do diagnostyki i terapii izotopowej z zastosowaniem pochodnych somatostatyny
- Augmented title (English)
- using technetium 99 and indium 111, lutetium 177
Publishing Information
- Journal Title
- Problemy Medycyny Nuklearnej
- Journal Volume
- 21
- Journal Issue
- 41,42
- Journal Page Range
- p. 59-62
- ISSN
- 0860-3405
INIS
- Country of Publication
- Poland
- Country of Input or Organization
- Poland
- INIS RN
- 39097351
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- DIAGNOSIS; INDIUM 111; INJECTION; LABELLED COMPOUNDS; PATIENTS; QUALITY CONTROL; RADIOPHARMACEUTICALS; SOMATOSTATIN; TECHNETIUM 99; THERAPY
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CONTROL; DAYS LIVING RADIOISOTOPES; DRUGS; ELECTRON CAPTURE RADIOISOTOPES; HOURS LIVING RADIOISOTOPES; INDIUM ISOTOPES; INTAKE; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LABELLED COMPOUNDS; MATERIALS; MEDICINE; MINUTES LIVING RADIOISOTOPES; NUCLEI; ODD-EVEN NUCLEI; RADIOACTIVE MATERIALS; RADIOISOTOPES; TECHNETIUM ISOTOPES; YEARS LIVING RADIOISOTOPES