Determination of the yield of a ferrous sulphate dosemeter in a 35 MeV electron beam

  • 1. CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Lab. de Metrologie des Rayonnements Ionisants

Description

The radiation chemical yield G(Fe3-) of the Fricke ferrous sulphate dosemeter has been measured in a 35 MeV initial energy electron beam. The reference absorbed dose in a graphite phantom was measured at the depth of the dose maximum using a graphite calorimeter. The Fricke solution was placed in graphite capsules with an internal polystyrene coating ensuring the secondary electron equilibrium in the solution. The value of G(Fe3+) thus obtained, for a solution without sodium chloride, is: G(Fe3+) = (1.627 +-0.017)μmolJ-1. (author)

Additional details

Additional titles

Original title (French)
Determination du rendment du dosimetre au sulfate ferreux dans un faisceau d'electrons de 35 MeV

Publishing Information

Journal Title
Phys. Med. Biol.
Journal Volume
27
Journal Issue
4
Series
Phys. Med. Biol.
Journal Page Range
583-596