Stability of a hot symmetric tandem mirror with thermal barrier

Description

It is shown that in general the stability of a hot electron symmetric tandem mirror is the same as the stability of its barrier-plug cell alone, plus an additional limitation on the center cell length such that the center cell Alfven frequency is higher than the average barrier-plug E x B drift and the hot electron precession frequency. Stability of the hot electron barrier-plug cell is studied extensively

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01 as DE85010539.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
32 p.
Report number
SAIC--85/1050-PRI-89

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16076096
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
ALFVEN WAVES; ELECTRON TEMPERATURE; STABILITY; SYMMETRY; TANDEM MIRRORS; THERMAL BARRIERS