Published January 2011 | Version v1
Journal article

Study on fatigue life evaluation using small specimens for testing neutron-irradiated materials

  • 1. Tohoku Univ., Dept. of Quantum Science and Energy Engineering, Sendai, Miyagi (Japan)
  • 2. Univ. of Fukui, Dept. of Mechanical Engineering, Fukui (Japan)
  • 3. Japan Atomic Energy Agency, Tokai, Ibaraki (Japan)
  • 4. National Inst. for Fusion Science, Toki, Gifu (Japan)

Description

The effect of specimen size and shape on the fatigue life of reduced activation ferritic/martensitic steel 'F82H IEA-heat' was investigated to develop a fatigue life evaluation method using a small specimen for testing neutron-irradiated materials. The fatigue test was carried out at room temperature in air using three kinds of round-bar specimen (minimum diameter cross sections of 1, 4, and 7 mm) and one hourglass specimen (minimum diameter cross section of 1.25 mm). The effect of specimen size on fatigue life from a level of 103 to 104 cycles was almost negligible for the round-bar specimens. The shorter fatigue life at the total strain range below 0.6% and the slightly longer fatigue life at the total strain range above 0.8% of the hourglass specimen relative to that of the standard specimen were observed from a level of 102 to 104 cycles. (author)

Availability note (English)

Available from http://dx.doi.org/10.3327/jnst.48.60

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo)
Journal Volume
48
Journal Issue
1
Journal Page Range
p. 60-64
ISSN
0022-3131

Optional Information

Notes
22 refs., 5 figs., 2 tabs.