Published August 2009 | Version v1
Journal article

Long-term safety and outcome of a temporary self-expanding metallic stent for achalasia: a prospective study with a 13-year single-center experience

  • 1. Shanghai Tong Ji University, Department of Radiology, Tenth Affiliated People's Hospital, Shanghai (China)
  • 2. Shanghai Jiao Tong University, Department of Radiology, Sixth Affiliated People's Hospital, Shanghai (China)
  • 3. Shanghai Jiao Tong University, Department of Gastroenterology, Sixth Affiliated People's Hospital, Shanghai (China)

Description

To prospectively evaluate the long-term clinical safety and efficacy of a newly designed self-expanding metallic stent (SEMS) in the treatment of patients with achalasia. Seventy-five patients with achalasia were treated with a temporary SEMS with a 30-mm diameter. The SEMSs were placed under fluoroscopic guidance and removed by gastroscopy 4-5 days after stent placement. Follow-up data focused on dysphagia score, technique and clinical success, clinical remissions and failures, and complications and was performed at 6 months, 1 year, and within 3 to 5 years, 5 to 8 years, 8 to 10 years, and >10 years postoperatively. Stent placement was technically successful in all patients. Complications included stent migration (n=4, 5.33%), chest pain (n=28, 38.7%), reflux (n=15, 20%), and bleeding (n=9, 12%). No perforation or 30-day mortality occurred. Clinical success was achieved in all patients 1 month after stent removal. The overall remission rates at 6 months, 1, 1-3, 3-5, 5-8, 8-10, and >10 year follow-up periods were 100%, 96%, 93.9%, 90.9%, 100%, 100%, and 83.3%, respectively. Stent treatment failed in six patients, and the overall remission rate in our series was 92%. The median and mean primary patencies were 2.8 ± 0.28 years (95% CI: 2.25-3.35) and 4.28 ± 0.40 years (95% CI: 3.51-5.05), respectively. The use of temporary SEMSs with 30-mm diameter proved to be a safe and effective approach for managing achalasia with a long-term satisfactory clinical remission rate. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-009-1373-y

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
19
Journal Issue
8
Journal Page Range
p. 1973-1980
ISSN
0938-7994
CODEN
EURAE3

Conference

Title
7. biennial international symposium of the International Society for Strategic Studies in Radiology (IS"3R)
Dates
23-25 Aug 2007
Place
Muenchen (Germany)

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
40084062
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; CHEST; ESOPHAGUS; IMPLANTS; VASCULAR DISEASES
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY