Published November 1989 | Version v1
Journal article

The problem of random fault in high power pulse modulator

Creators

  • 1. Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

Description

In the long-term operation of electron Linac, we encountered the continuous conduct problem of main thyratron in high power pulse modulator. It can cause random fault. The reason is that synchronization trigger to provide trigger pulse may produce random pulse, therefore a lot of anti-interference are used in synchronization trigger. A 'Self-locking circuit' is specially designed. By means of these measures, the problem of random fault in high power pulse modulator is solved, and stable operation of electron linac is assured

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
23
Journal Issue
6
Series
At. Energy Sci. Technol.
Journal Page Range
63-64
ISSN
1000-6931
CODEN
YKJIE