Cooled organic insulant test experimental data report

Description

A proposed method of insulating hot coolant tubes from the moderator in an organic cooled reactor is to use a thin organic insulating annulus. The experiment reported here was a preliminary in-reactor experiment in which a water cooled thimble was insulated from the hot organic in the test section of the X-7 loop in NRX, Approximate measurements of the heat-transfer coefficient across the annulus were made during the test and the annulus was sectioned and examined following the irradiation. The total integrated flux seen by the annulus during the two months irradiation was approximately 1.37 x 1020 n/ cm2 (nV ot). The average bulk organic temperature was approximately 550oF. This resulted in little or no fouling in the annulus and no significant rise in the overall heat transfer coefficient across the annulus. The report contains details of the operating conditions of the experiment and of the post-irradiation examination, including photographs taken in the cell. (author)

Files

43123845.pdf

Files (18.8 MB)

Name Size Download all
md5:b86a4d1a39d6974bca1efd79aa006214
18.8 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
43 p.
Report number
AECL--1455

Optional Information

Notes
11 refs., 7 tabs., 16 figs.
Secondary number(s)
Exp-NRX--70103