Published August 2003 | Version v1
Journal article

An experimental study of critical heat flux in non-uniformly heated vertical annulus under low flow conditions

  • 1. KAERI, Taejon (Korea, Republic of)
  • 2. Tokyo Institute of Technology, Tokyo (Japan)

Description

An experimental study on Critical Heat Flux (CHF) has been performed in an internally heated vertical annulus with non-uniform heating. The CHF data for the chopped cosine heat flux have been compared with those for uniform heat flux obtained from the previous study of the authors, in order to investigate the effect of axial heat flux distribution on CHF. The local CHF with the parameters such as mass flux and critical quality shows an irregular behavior. However, the total critical power with mass flux and the average CHF with critical quality are represented by a unique curve without the irregularity. The effect of the heat flux distribution on CHF is large at low pressure conditions but becomes rapidly smaller as the pressure increases. The relations-hip between the critical quality and the boiling length is represented by a single curve, independent of the axial heat flux distribution. For non-uniform axial heat flux distribution, the prediction results from Doerffer et al.'s and Bowring's CHF correlations have considerably large errors, compared to the prediction for uniform heat flux distribution

Additional details

Publishing Information

Journal Title
KSME International Journal
Journal Volume
17
Journal Issue
8
Series
19 refs, 20 figs, 2 tabs
Journal Page Range
p. 1171-1184
ISSN
1226-4865

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
36106169
Subject category
S42: ENGINEERING;
Descriptors DEI
ANNULAR SPACE; BOILING; BOUNDARY LAYERS; CRITICAL HEAT FLUX; HEATING; NUCLEAR FUELS; REACTOR ACCIDENTS
Descriptors DEC
ACCIDENTS; CONFIGURATION; ENERGY SOURCES; FUELS; HEAT FLUX; LAYERS; MATERIALS; PHASE TRANSFORMATIONS; REACTOR MATERIALS; SPACE