The integral dose and the dose to the organ at risk were calculated using the following angiographic techniques: 1. Intravenous DSA in the neck, 2. Intravenous DSA in the skull, 3. Intra-arterial DSA in the skull in searching for an aneurysm. This was compared with 4. 105 mm camera technique and 5. An imaging plate technique. These methods have been compared with reference to dose and diagnostic value. Desirable developments for angiography in the future are discussed. (orig.)

Abstract (German)

Fuer die folgenden Angiographietechniken werden die Integraldosis und die Dosis in Risikoorganen angegeben. 1. intravenoese DSA im Halsbereich, 2. intravenoese DSA im Kopfbereich, 3. intraarterielle DSA im Kopfbereich 'Aneurysmasuche' im Vergleich mit 4. 105-mm-Kameratechnik und 5. IP-Imaging-Plate-Technik. Unter Beruecksichtigung der Dosisbelastung und der diagnostischen Aussagefaehigkeit werden die Methoden einander gegenuebergestellt. Aussserdem wird ueber die wuenschenswerte Entwicklung der verschiedenen Angiographiemethoden fuer die Zukunft diskutiert. (orig.)

Additional details

Additional titles

Original title (German)
Dosisbelastung und Wertigkeit bei der kranialen Angiographie - digital i.v., i.a., Kamera (105 mm) und Imaging-Plates

Publishing Information

Journal Title
RoeFo - Fortschr. Geb. Roentgenstr. Nuklearmed.
Journal Volume
147
Journal Issue
6
Series
RoeFo - Fortschr. Geb. Roentgenstr. Nuklearmed.
Journal Page Range
676-679
ISSN
0340-1618
CODEN
RFGND