Published January 1975 | Version v1
Report Restricted

DNB test results for R grid thimble cold wall cells

Description

Two sets of type ''R'' mixing vane grid DNB data from a 4 x 4 rod bundle, where one of the central rods is a simulated control rod thimble, are presented. The range of parameters for this thimble cold wall data is given. The results show that the W-3 correlation with cold wall factor and the Modified Spacer Factor is applicable to ''R'' grid thimble cold wall rod bundle data. (7 references) (auth)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
PWR

Publishing Information

Imprint Pagination
32 p.
Report number
WCAP--7958(Add.1-A)

Optional Information

Notes