Published 2024
| Version v1
Journal article
Reinvestigation of Sr and Y atomic masses using the JYFLTRAP Penning trap
Creators
- 1. Department of Physics, Accelerator Laboratory, University of Jyvaskyla, P.O. Box 35(YFL), 40014, University of Jyvaskyla (Finland)
Description
We report on the precise mass measurements of the Sr and Y isotopes performed using the JYFLTRAP double Penning trap mass spectrometer. The mass-excess values from this work, ME(Sr) = -83645.5(13) keV and ME(Y) = -81226.4(10) keV, deviate by 6.5(52) keV and -18(7) keV from the Atomic Mass Evaluation 2020 (AME20). In the case of Sr the new result disagrees with the ISOLTRAP value, while for Y, it agrees with the older JYFLTRAP value.
Availability note (English)
Available from: http://dx.doi.org/10.1140/epja/s10050-024-01248-zAdditional details
Identifiers
Publishing Information
- Journal Title
- European Physical Journal. A, Hadrons and Nuclei (Internet)
- Journal Volume
- 60
- Journal Issue
- 2
- Journal Page Range
- vp.
- ISSN
- 1434-601X
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 55091644
- Subject category
- S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
- Descriptors DEI
- MASS; MASS SPECTROMETERS; TRAPS; YTTRIUM ISOTOPES
- Descriptors DEC
- ISOTOPES; MEASURING INSTRUMENTS; SPECTROMETERS
Optional Information
- Notes
- AID: 37