Published February 22, 2022 | Version v1
Journal article

Myocardial perfusion quantification with Rb-82 PET. Good interobserver agreement of Carimas software on global, regional, and segmental levels

  • 1. University of Turku, Turku University Hospital. Turku PET Centre, Turku (Finland)
  • 2. University of Lausanne, Lausanne (Switzerland)

Description

Purpose

To estimate the interobserver agreement of the Carimas software package (SP) on global, regional, and segmental levels for the most widely used myocardial perfusion PET tracer-Rb-82.

Materials and methods

Rest and stress Rb-82 PET scans of 48 patients with suspected or known coronary artery disease (CAD) were analyzed in four centers using the Carimas SP. We considered values to agree if they simultaneously had an intraclass correlation coefficient (ICC) > 0.75 and a difference < 20% of the median across all observers.

Results

The median values on the segmental level were 1.08 mL/min/g for rest myocardial blood flow (MBF), 2.24 mL/min/g for stress MBF, and 2.17 for myocardial flow reserve (MFR). For the rest MBF and MFR, all the values at all the levels fulfilled were in excellent agreement. For stress MBF, at the global and regional levels, all the 24 comparisons showed excellent agreement. Only 1 out of 102 segmental comparisons (seg. 14) was over the adequate agreement limit-23.5% of the median value (ICC = 0.95).

Conclusion

Interobserver agreement for Rb-82 PET myocardial perfusion quantification analyzed with Carimas is good at any LV segmentation level-global, regional, and segmental. It is good for all the estimates-rest MBF, stress MBF, and MFR. (author)

Additional details

Identifiers

Publishing Information

Journal Title
Annals of Nuclear Medicine
Journal Volume
36
Journal Issue
6
Journal Page Range
p. 507-514
ISSN
0914-7187
CODEN
ANMEEX

Optional Information

Copyright
Copyright (c) 2022 © The Author(s) 2022