Dependence of renal blood flow on renal artery stenosis measured using CT angiography
Creators
- 1. Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiotherapy
- 2. Charite - Universitaetsmedizin Berlin (Germany). Inst. for Vegetative Physiology
- 3. Krankenhaus am Urban, Berlin (Germany). Dept. of Anesthesiology
- 4. Charite - Universitaetsmedizin Berlin (Germany). Experimental Animal Unit
- 5. Univ. Leipzig/ Leipzig Heart Center (Germany). Dept. of Diagnostic and Interventional Radiology
- 6. Charite - Universitaetsmedizin Berlin (Germany). Dept. of Diagnostic and Interventional Radiology
- 7. Bayer-Schering Pharma AG, Berlin (Germany). Global Medical Affairs Diagnostic Imaging
Description
The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)
Additional details
Publishing Information
- Journal Title
- RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
- Journal Volume
- 183
- Journal Issue
- 3
- Journal Page Range
- p. 267-273
- ISSN
- 1438-9029
- CODEN
- RFGNDO
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 42082337
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLOOD FLOW; COMPUTERIZED TOMOGRAPHY; KIDNEYS; UROGENITAL SYSTEM DISEASES
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; ORGANS; TOMOGRAPHY