Published 1988 | Version v1
Book

Characterization of a centrifugal pump in He II

  • 1. Univ. of Wisconsin, Madison (USA)

Description

To determine helium transfer feasibility in space a pump was tested at a variety of flow rates, pump speeds, and fluid temperatures. The pump generated a maximum pressure rise of 15 kPa and a maximum flow rate of 22 g/s. Pump performance seemed independent of fluid temperature. Measured maximum efficiency was around 50% over the range of flow coefficients. Cavitation was observed and thought to be dependent on local helium heating in the pump. Preliminary noise spectra measurements suggested a mechanism to predict cavitation onset

Additional details

Publishing Information

Publisher
Plenum Press.
Imprint Place
New York, NY (USA)
Imprint Title
Advances in cryogenic engineering. Volume 33
Journal Page Range
p. 507-514.

Conference

Title
Cryogenic engineering conference.
Dates
14-18 Jun 1987.
Place
St. Charles, IL (USA).