Published February 2, 2001 | Version v1
Report

Common Mode Rejection Calculations on the Debuncher Upgrade

Description

The 4-8 GHz Transverse Debuncher Cooling Systems are power limited. Misalignments and imperfections in the transverse pickup arrays will generate a longitudinal signal in addition to the betatron signal. This longitudinal signal can use up a significant fraction of the precious TWT power if the imperfections are large enough. This note will summarize calculations of the contributions to the longitudinal signal observed in the transverse systems of the 4-8 GHz Debuncher slow-wave pickup arrays due to various misalignments and imperfections.

Availability note (English)

Available from http://lss.fnal.gov/cgi-bin/find_paper.pl?pbar-651.pdf; PURL: https://www.osti.gov/servlets/purl/984583-nSulUk/

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
FERMILAB-PBAR-NOTE--651

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
41108972
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
BETATRONS; COOLING SYSTEMS; DEFECTS
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; ENERGY SYSTEMS

Optional Information

Contract/Grant/Project number
AC02-76CH03000
Notes
doi 10.2172/984583
Funding organization
US Department of Energy (United States)