The Bruce B delayed neutron (DN) monitoring system for failed fuel detection: twenty years of operating experience, recent improvements, and planned upgrades

  • 1. Bruce Power Inc., Tiverton, Ontario (Canada)

Description

The Delayed Neutron (DN) Monitoring System installed at the Bruce B reactor units has proven to be a powerful tool for the on-line determination of the reactor channel in which a fuel failure has occurred. It allows us to observe, in spite of occasionally noisy raw data, detailed information about a defect and the activity remaining in the affected channel following the removal of the failed fuel bundle. The system sensitivity has not deteriorated significantly over 20 years of operation. A recently developed analysis algorithm has led to a strong improvement in the defect signature to noise ratio. (author)

Part of:
Nuclear energy: meeting the challenges

Additional details

Publishing Information

Publisher
Canadian Nuclear Society, Toronto, Ontario, Canada.
Imprint Place
Toronto, Ontario (Canada)
ISBN
0-919784-79-8
Imprint Title
Nuclear energy: meeting the challenges
Imprint Pagination
159 Megabytes
Journal Page Range
[11 p.]

Conference

Title
25. annual CNS conference
Dates
6-9 Jun 2004
Place
Toronto, Ontario (Canada)

INIS

Optional Information

Notes
2 refs., 1 tab., 6 figs.