Published December 2019 | Version v1
Journal article

Low dose bath from IMPT vs. IMXT for the pelvic area when treating advanced prostate cancer

  • 1. Department of Health Care Disciplines and Population Protection, Faculty of Biomedical Engineering, Czech Technical University in Prague, Sitna square 3105, 272 01 Kladno (Czech Republic)
  • 2. Proton Therapy Center Czech, Budinova 1a, 18000 Prague 8 (Czech Republic)
  • 3. Department of Health Protection and Disaster Medicine, Pavlov First Saint Petersburg State Medical University, L'va Tolstogo str. 6-8, 197022 Saint Petersburg (Russian Federation)

Description

Twenty (10 intensity-modulated proton therapy (IMPT) and 10 intensity-modulated x-ray therapy (IMXT) treatment plans for patients with advanced prostate carcinoma were compared in this study. All chosen patients were indicated for prostate and pelvic lymph nodes irradiation using simultaneous integrated boost technique. These patients represent typical specimen for this diagnose. IMPT irradiates just half of the tissue volume with a low dose (up to 10 cobalt gray equivalent) compared to IMXT without compromise in target volumes coverage and in this way reduces the risk of secondary cancer development or other possible complications. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncz235

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
186
Journal Issue
2-3
Journal Page Range
p. 377-380
ISSN
0144-8420

Optional Information

Notes
27 refs.