Published March 2013 | Version v1
Journal article

Cold test simulation method for double-gap output circuit with double coupling apertures

  • 1. Graduate University of Chinese Academy of Sciences, Beijing (China)
  • 2. Key Laboratory of High Power Microwave Sources and Technologies, Institute of Electronics, Chinese Academy of Sciences, Beijing (China)

Description

Based on microwave net theory, a cold test simulation model of double-gap output circuit with double coupling apertures was developed from that of output circuit with single coupling aperture. A computation method for gap impedance was also developed based on this model, by which the real part and imaginary part of the gap impedance can be both obtained. Meanwhile, a double-gap cavity with double coupling apertures for an S band klystron was simulated to show how to compute the gap impedance and external quality factor of the output cavity with this simulation method, and the computed result is verified to be reasonable in theory. The computed result was analyzed and compared with those obtained with the field analysis method and the scattering parameter of output circuit, confirming the reliability of this cold test simulation method. (authors)

Additional details

Publishing Information

Journal Title
High Power Laser and Particle Beams
Journal Volume
25
Journal Issue
3
Journal Page Range
p. 675-679
ISSN
1001-4322

Optional Information

Notes
7 figs., 10 refs.