Published 1975 | Version v1
Journal article

Determination of the neutron- and γ-sensitivity of a Rh-SPN-dedector

  • 1. Gesellschaft fuer Kernenergieverwertung in Schiffbau und Schiffahrt m.b.H., Geesthacht-Tesperhude (F.R. Germany). Inst. fuer Werkstofftechnologie
  • 2. Teheran Univ. (Iran). Nuclear Centre

Description

Measurements with a Rh-SPN-detector were carried out to determine the contributions of thermal and epithermal neutrons and gamma radiation to the current signal. The detector was used to measure the neutron flux distribution in a peripherical position of the MTR swimming pool reactor FRG-2 at Geesthacht. The maximum operating power was 15 MW. A method is described in order to measure the thermal neutron sensitivity and the γ-sensitivity of the Rh-SPN-detector. (orig.)

Abstract (German)

Es wurden Messungen mit einem Rh-SPN-Detektor durchgefuehrt, um die Beitraege von thermischen und epithermischen Neutronen sowie der Gammastrahlung am Stromsignal zu bestimmen. Mit diesem Detektor wurde in einer aeusseren Core-Position des MTR-Swimming-Pool-Reaktors FRG-2 in Geesthacht die Neutronenflussverteilung gemessen. Die maximale Betriebsleistung betrug 15 MW. Es wird eine Methode zur Messung der thermischen Neutronen- und Gammaempfindlichkeit eines Rh-SPN-Detektors beschrieben. (orig.)

Additional details

Publishing Information

Journal Title
Atomkernenergie
Journal Volume
26
Journal Issue
1
Series
Atomkernenergie.
Journal Page Range
25-28

Optional Information

Notes
8 figs.; 2 tabs.; 7 refs.