Published July 2002
| Version v1
Journal article
First results of the new scanning transmission X-ray microscope at BESSY-2
Creators
- 1. Gottingen Universitat, Institute for X-Ray Physics (Germany)
- 2. RheinAhrCampus Remagen (Germany)
- 3. Royal Institute of Technology/SCFAB, Biomedical and X-Ray Physics, Stockholm (Sweden)
Description
A new scanning transmission X-ray microscope (STXM) has been built at the undulator U41 of the BESSY II storage ring. The STXM monochromator consists of a plane mirror and a plane grating with varied line density. First NEXAFS spectra of a polyimide foil at the carbon, nitrogen and oxygen K absorption edges are shown. The photon rate in the focal spot is about 10 MHz at the carbon and about 500 MHz at the oxygen K absorption edge. The first images are presented. (authors)
Additional details
Publishing Information
- Journal Title
- Journal de Physique. 4
- Journal Volume
- 104
- Journal Page Range
- p. 95-98
- ISSN
- 1155-4339
- CODEN
- JPICEI
Conference
- Title
- 7. international conference on X-Ray microscopy - X-Ray microscopy 2002
- Dates
- 28 Jul - 2 Aug 2002
- Place
- Grenoble (France)
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 34066036
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM OPTICS; BESSY STORAGE RING; OPTICAL MICROSCOPES; PERFORMANCE; X RADIATION
- Descriptors DEC
- ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MICROSCOPES; RADIATIONS; STORAGE RINGS
Optional Information
- Notes
- 7 refs.