Published September 1, 2014
| Version v1
Journal article
Particle identification system based on dense aerogel for SND detector at VEPP-2000 collider
Creators
- 1. Budker Institute of Nuclear Physics, 11, akademika Lavrentieva prospect, Novosobirsk 630090 (Russian Federation)
- 2. Boreskov Institute of Catalysis, 5, akademika Lavrentieva prospect, Novosibirsk 630090 (Russian Federation)
Description
The threshold Čerenkov counter based on dense aerogel with refraction index n =1.13 is described. This counter is used for π/K separation at SND detector at VEPP-2000 e+e− collider in the particle momentum range up to 1 GeV/c. The results on separation efficiency for hadrons produced in e+e− annihilation are presented
Availability note (English)
Available from http://dx.doi.org/10.1088/1748-0221/9/09/C09023Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Instrumentation
- Journal Volume
- 9
- Journal Issue
- 09
- Journal Page Range
- p. C09023
- ISSN
- 1748-0221
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46063980
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ANNIHILATION; EFFICIENCY; GEV RANGE; HADRONS; PARTICLE IDENTIFICATION; POSITRONS; REFRACTION
- Descriptors DEC
- ANTILEPTONS; ANTIMATTER; ANTIPARTICLES; ELEMENTARY PARTICLES; ENERGY RANGE; FERMIONS; INTERACTIONS; LEPTONS; MATTER; PARTICLE INTERACTIONS