A large break pipe accident of the AP600 reactor coolant system (RCS) pressure boundary

  • 1. Center for Development of Nuclear Safety Technology, National Nuclear Energy Agency, Serpong (Indonesia)

Description

The large break pipe accident for AP600 has been analyzed. The analysis was done to evaluate the performance of protection system (Reactor Trip followed by Pump Trip) and mitigation system (CMT, ACC and IRWST) of the AP600 in order to limit the maximum fuel element cladding temperature so it does not exceed the acceptance criteria. Based on the accident sequences determined, the simulation was done by using PCTRAN Code. The analysis shows that the peak cladding temperature (PCT) which be reached is 698,8oC in case of cold leg break.This PCT is of course below the regulatory limit of 2200 of (1204oC) in the 10 CFR 50.46

Files

31042151.pdf

Files (151.7 kB)

Name Size Download all
md5:cf60367df1fe667d752bd30d2bfd9732
151.7 kB Preview Download
Part of:
Proceedings of the Fourth Scientific Presentation on Reactor Safety Technology

Additional details

Additional titles

Original title (Indonesian)
Kecelakaan pipa pecah ukuran besar pada sistem primer reaktor daya AP600

Publishing Information

Imprint Title
Proceedings of the Fourth Scientific Presentation on Reactor Safety Technology
Imprint Pagination
203 p.
Journal Page Range
p. 14-22
ISSN
1410-0533
Report number
INIS-ID--004

Conference

Title
4. Scientific Presentation on Reactor Safety Technology
Original Conference Title
Presentasi Ilmiah Teknologi Keselamatan Reaktor IV
Dates
5 May 1999
Place
Serpong (Indonesia)

Optional Information

Notes
5 refs.; 1 tab.; 4 figs. Imprint:Prosiding presentasi ilmiah teknologi keselamatan nuklir IV