Published November 1993 | Version v1
Report Restricted

Criticality safety studies of Building 3019 Cell 4 and in-line storage wells

Description

New fissile material load limits for storage facilities located in Building 3019 are derived in a manner consistent with currently applicable Martin Marietta Energy Systems requirements. The limits for 233U loading are 2.00, 1.80, 1.45, and 0.19 kg/ft for hydrogen-to-233U atoms ratios of 3, 5, 10, and unrestricted, respectively. Limits were also found for 235U and 239Pu systems. The KENO-Va Monte Carlo Program and Hansen-Roach cross sections were used to derive these limits

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95016201; NTIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
151 p.
Report number
ORNL/TM--12374

Optional Information

Contract/Grant/Project number
Contract AC05-84OR21400
Funding organization
USDOE, Washington, DC (United States).