Published February 1993 | Version v1
Journal article

Modifications to installed Sphincter design gloveports

Description

This paper presents the results of a study of alternative methods for replacing Sphincter designed gloveports in gloveboxes. In addition, the paper discusses modifications that are required on metal glovebox wall panels to allow replacement of the Sphincter gloveports. A review of Westinghouse Savannah River Co. (WSRC) maintenance records showed that gloveports manufactured by Central Research, Incorporated, provide the lowest risk for failure. This assessment is based on the records of glove-to-port seal life and air in-leakage. These records also indicate the glove changes are made in shorter times with fewer workers than required by alternate gloveport designs studied. These attributes culminate in a significant decrease in radiation exposure and assimilation risk of maintenance personnel replacing gloves. Further, the Central Research design reduces the number of expandable hardware parts required to achieve a glove replacement. This reduction in expendable materials can result in a significant reduction in contaminated waste volume generated during a glove replacement

Additional details

Publishing Information

Journal Title
Enclosure
Journal Volume
6
Journal Issue
1
Journal Page Range
p. 4-6.
CODEN
ECLOEP