Electronic dose conversion technique using a NaI(Tl) detector for assessment of exposure dose rate from environmental radiation

  • 1. Korea Advanced Inst. of Science and Technology, Taejon (Korea, Republic of)
  • 2. Korea Electric Power Research Inst., Taejon (Korea, Republic of)
  • 3. Samchang Enterprise Co., Anyang (Korea, Republic of)

Description

An electronic dose conversion technique to assess the exposure dose rate due to environmental radiation especially from terrestrial sources was developed. For a 2 x 2 inch cylindrical NaI(Tl) scintillation detector, pulse-height spectra were obtained for gamma-rays of energy up to 3 MeV by Monte Carlo simulation. Based on the simulation results and the experimentally fitted energy resolution, dose conversion factors were calculated by a numerical decomposition method. These calculated dose conversion factors were, then, electronically implemented to a developed dose conversion unit (DCU) which is a microprocessor-controlled single channel analyzer (SCA) with variable discrimination levels. The simulated spectra were confirmed by measurement of several monoenergetic gamma spectra with a multichannel analyzer (MCA). The converted exposure dose rates from the implemented dose conversion algorithm in the DCU were also evaluated for a field test in the vicinity of the nuclear power plant at Kori as well as for several standard sources, and the results were in good agreement with separate measurement by a high pressure ionization chamber (HPIC) within a 6.4% deviation

Additional details

Publishing Information

Journal Title
IEEE Transactions on Nuclear Science
Journal Volume
45
Journal Issue
3Pt1
Journal Page Range
p. 981-985
ISSN
0018-9499
CODEN
IETNAE

Conference

Title
Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference
Dates
11-13 Nov 1997
Place
Albuquerque, NM (United States)

Optional Information

Secondary number(s)
CONF-971147--