Published November 1979 | Version v1
Journal article

Sealing of knife-edge flanges after a high temperature vacuum firing

  • 1. Brookhaven National Laboratory, Upton, New York 11973

Description

A 2 3/4-in. Varian flange has been vacuum fired at 9000C for four hours and found to seal without leakage through each of 40 separate closures. This indicates that such a flange may in fact be sufficient for the ISABELLE ultrahigh vacuum system without knife-edge modification

Additional details

Publishing Information

Journal Title
J. Vac. Sci. Technol.
Journal Volume
16
Journal Issue
6
Series
J. Vac. Sci. Technol.
Journal Page Range
2114
ISSN
0022-5355