Improving the Definition of Tumor Bed Boost With the Use of Surgical Clips and Image Registration in Breast Cancer Patients
Creators
- 1. Department of Radiation Oncology, Institut Curie, Paris (France)
- 2. Department of Surgery, Institut Curie, Paris (France)
- 3. Department of Pathology, Institut Curie, Paris (France)
Description
Purpose: To evaluate the accuracy of a boost technique. Methods and Materials: Twenty-two patients underwent tumorectomy with placement of two or more clips in the surgical cavity before breast remodeling. Preoperative and postoperative computed tomography scans, with match-point registration, were performed on all patients. The relationship between the location of the gross tumor volume (GTV), defined on the preoperative scan, and clip clinical target volume (CTV) (clips with a 5-mm margin on the postoperative scan) was then studied, by use of commercial volume analysis software. Results: Of the patients, 4 had two clips, 2 had three clips, 8 had four clips, and 8 had five clips. The median GTV was 1.06 mL (range, 0.2-5.3 mL); clip CTV ranged from 2.4 to 21.5 mL. Volumetric analysis showed that in 7 cases (32%), there was no intersection between the GTV and the clip CTV, with the following distribution: 4 patients with two clips, 1 patient with three clips, 1 patient with four clips, and 1 patient with five clips. The common contoured volume was defined as the percent ratio between the intersection of the GTV and clip CTV and the GTV. It was found to be significantly increased if three or more clips were used vs. only two clips (common contoured volume, 35.45% vs. 0.73%; p = 0.028). Finally, the GTV and clip CTV volume relationship can be presented as follows: 12.5% to 33% overlap in 8 patients (36.4%), 50% to 75% in 5 patients (22.7%), and greater than 90% in 2 patients (9%). Conclusions: The use of three or more clips during tumorectomy increases the accuracy of tumor bed delineation.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ijrobp.2009.10.049Additional details
Identifiers
- DOI
- 10.1016/j.ijrobp.2009.10.049;
- PII
- S0360-3016(09)03525-1;
Publishing Information
- Journal Title
- International Journal of Radiation Oncology, Biology and Physics
- Journal Volume
- 78
- Journal Issue
- 5
- Journal Page Range
- p. 1352-1355
- ISSN
- 0360-3016
- CODEN
- IOBPD3
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42083177
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; CAT SCANNING; MAMMARY GLANDS; NEOPLASMS; RADIOTHERAPY; SURGERY; VOLUMETRIC ANALYSIS
- Descriptors DEC
- BODY; CHEMICAL ANALYSIS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; QUANTITATIVE CHEMICAL ANALYSIS; RADIOLOGY; THERAPY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.