Published August 28, 1998 | Version v1
Journal article

Determination of left ventricular mass through SPECT imaging

  • 1. Facultad de Ciencias-UNAM, Ciudad Universitaria, 04510 Mexico D.F., (Mexico)
  • 2. Instituto de Fisica-UNAM, A.P. 20-364, 01000 Mexico D.F., (Mexico)
  • 3. Hospital de Cardiologia, CMN Siglo XXI, Av. Cuauhtemoc 330, Col. Doctores, 04620 Mexico D.F. (Mexico)

Description

An edge detection algorithm has been applied to estimate left ventricular (LV) mass from single photon emission computed tomography (SPECT) thallium-201 images. The algorithm was validated using SPECT images of a phantom. The algorithm was applied to 20 patient studies from the Hospital de Cardiologia, Centro Medico Nacional Siglo XXI. Left ventricular masses derived from the stress and redistribution studies were highly correlated (r=0.96). The average LV masses obtained were 162±37 g and 169±34 g in the redistribution and stress studies, respectively

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
440
Journal Issue
1
Journal Page Range
p. 107-115
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
2. Mexican symposium on medical physics
Dates
26-28 Feb 1998
Place
Coyoacan (Mexico)

Optional Information

Notes
(c) 1998 American Institute of Physics.