Influence of atomic and nuclear constants on the counting effiency for 55Fe in liquid ascintillators

  • 1. Junta de Energia Nuclear, Madrid (Spain)
  • 2. Univ. Autonoma de Sto. Domingo (Rep. Dominicana)

Description

In this paper one considers the influence of the different parameters on the determination of the uncertainty of the detection efficiency for 55Fe when the counting technique of liquid scintillation is applied. The following parameters are considered: the relative probabilities of X and Auger emission so as their corresponding energies, the fluorescence yields Wsub(K) and Wsub(L) and the non-interaction probabilities of the emitted X photons. (author)

Availability note (English)

MF available from INIS under the Report Number.

Additional details

Additional titles

Original title (Spanish)
Influencia de los parametros atomicos y moleculares en la calibracion de

Publishing Information

Imprint Pagination
36 p.
Report number
JEN--572

Optional Information

Notes
24 figs.; 11 refs.