Published June 11, 1976 | Version v1
Report Restricted

Preliminary design review document application of multi-foil insulation to the Brayton Isotope Power System and conceptual design of multi-foil insulation for the flight system (phase I)

Description

The status of the effort to apply MULTI-FOIL thermal insulation in an effective manner to the Ground Development System (GDS) is reviewed. Heat loss measurements made on cylindrical and elbow heat sources using ''Tape'' and ''Conventional'' MULTI-FOIL indicate that the thermal losses are comparable on a per layer basis. However, use of the tape incurs a weight penalty, per layer, of about 20 percent. The effective thermal emissivity of the nickel layer/zirconia powder MULTI-FOIL is approximately 0.32. Parametric studies of GDS insulation losses (using a computer program developed for this purpose) indicate: (1) that the Heat Source Assembly (HSA) heat losses are a major fraction of the total and (2) that a significant reduction in heat loss is possible by optimizing the distribution of foil layers. A meltdown test of a miniature HSA configuration suggests that additional MULTI-FOIL layers can be safety added to the HSA insulation. Test data indicate that ''Electroformed'' MULTI-FOIL insulation assemblies (as a consequence of decreased edge loss and lower foil emissivity) are approximately four times as effective as either ''Conventional'' or ''Tape'' MULTI-FOIL packages on a weight basis. Preliminary GDS insulation design and planning have been completed

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
83 p.
Report number
TE--4209-100-76

Optional Information

Notes
Available from NTIS. $5.00.