Published September 1993 | Version v1
Report Open

Operation of Finnish nuclear power plants

Description

Quarterly reports on the operation of Finnish nuclear power plants describe events and observations, relating to nuclear safety and radiation protection which the Finnish Centre for Radiation and Nuclear Safety considers safety significant. Safety-enhancing modifications at the nuclear power plants and issues relating to the use of nuclear energy which are of general interest are also reported. The reports include a summary of the radiation safety of plant personnel and the environment, as well as tabulated data on the production and load factors of the plants. In the first quarter of 1993, a primary feedwater system pipe break occurred at Loviisa 2, in a section of piping after a feedwater pump. The break was erosion-corrosion induced. Repairs and inspections interrupted power generation for seven days. On the International Nuclear Event Scale the event is classified as a level 2 incident. Other events in the first quarter of 1993 had no bearing on nuclear safety and radiation protection

Availability note (English)

MF available from INIS under the Report Number.

Files

25000869.pdf

Files (671.9 kB)

Name Size Download all
md5:d09c220a0f6f05cdaac4685ca897a76b
671.9 kB Preview Download

Additional details

Additional titles

Subtitle (English)
Quarterly report 1 st quarter, 1993

Publishing Information

ISBN
951-47-8170-8
Imprint Pagination
23 p.
Report number
STUK-B-YTO--110

Optional Information

Notes
Published also in Finnish as report number STUK-B-YTO--108.