The clinical value of MRA at 3.0 T for the diagnosis and therapeutic planning of patients with subarachnoid haemorrhage
Creators
- 1. Shanghai Jiao Tong University, Institute of Diagnostic and Interventional Radiology, The Sixth Affiliated People's Hospital, Shanghai (China)
- 2. Shanghai Jiao Tong University, Department of Neurosurgery, Sixth Affiliated People's Hospital, Shanghai (China)
Description
To evaluate the clinical value of unenhanced magnetic resonance angiography (MRA) at 3.0 T for the diagnosis and therapeutic planning of patients with subarachnoid haemorrhage (SAH). A total of 165 patients with SAH were referred for three-dimensional time-of-flight MRA (3D-TOF-MRA) before digital subtraction angiography (DSA). For each aneurysm, 3D-TOF-MRA was used to determine whether the aneurysm was suitable for coil placement with or without balloon/stent-assisted coiling, surgical clipping or conservative treatment. Treatment planning with 3D-TOF-MRA was compared with actual treatment decisions or treatment that had been carried out in each aneurysm decided using DSA. The aneurysm-based evaluation yielded accuracy of 96.9%, sensitivity of 97.6%, specificity of 93.1%, positive predictive value (PPV) of 98.8% and negative predictive value (NPV) of 87.1%, in the detection of intracranial aneurysms. Treatment planning could be correctly made on the basis of aneurysm anatomy and working view by volume rendering (VR) 3D-TOF-MRA with accuracy, sensitivity, specificity, PPV and NPV of 94.9%, 94.0%, 100%, 100% and 74.4%, respectively, on a per aneurysm-based evaluation. VR 3D-TOF-MRA offers high diagnostic accuracy in the detection of ruptured intracranial aneurysms, and appears to be an effective treatment planning tool for most patients with SAH. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-012-2390-9Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 22
- Journal Issue
- 7
- Journal Page Range
- p. 1404-1412
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 43076222
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ARTERIES; BIOMEDICAL RADIOGRAPHY; BLOOD VESSELS; DIAGNOSIS; HEMORRHAGE; IMAGE PROCESSING; MAGNETIC FIELDS; NMR IMAGING; PLANNING; RELAXATION TIME; SENSITIVITY; SPECIFICITY; SURGERY; THERAPY; TIME-OF-FLIGHT METHOD; WEIGHTING FUNCTIONS
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; FUNCTIONS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; RADIOLOGY; SYMPTOMS