Recalibration of indium foil for personnel screening in criticality accidents
Creators
- 1. Japan Atomic Energy Agency, 4-33, Tokai-mura, Ibaraki-ken 319-1194 (Japan)
Description
At the Nuclear Fuel Cycle Engineering Laboratories of the Japan Atomic Energy Agency (JAEA), small pieces of indium foil incorporated into personal dosemeters have been used for personnel screening in criticality accidents. Irradiation tests of the badges were performed using the SILENE reactor to verify the calibration of the indium activation that had been made in the 1980's and to recalibrate them for simulated criticalities that would be the most likely to occur in the solution process line. In addition, Monte Carlo calculations of the indium activation using the badge model were also made to complement the spectral dependence. The results lead to a screening level of 15 kcpm being determined that corresponds to a total dose of 0.25 Gy, which is also applicable in posterior-anterior exposure. The recalibration based on the latest study will provide a sounder basis for the screening procedure in the event of a criticality accident. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncq342Additional details
Identifiers
- DOI
- 10.1093/rpd/ncq342;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 144
- Journal Issue
- 1-4
- Journal Page Range
- p. 575-579
- ISSN
- 0144-8420
Conference
- Title
- European conference on individual monitoring of ionising radiation
- Acronym
- IM2010
- Dates
- 8-12 Mar 2010
- Place
- Athens (Greece)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 43077551
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CALIBRATION; CRITICALITY; DOSEMETERS; HAZARDS; HUMAN POPULATIONS; INDIUM; IRRADIATION; JAEA; MONTE CARLO METHOD; RADIATION ACCIDENTS; RADIATION MONITORING; RADIATION PROTECTION; SILENE REACTOR; THERMOLUMINESCENT DOSIMETRY
- Descriptors DEC
- ACCIDENTS; CALCULATION METHODS; DOSIMETRY; ELEMENTS; ENRICHED URANIUM REACTORS; EXPERIMENTAL REACTORS; JAPANESE ORGANIZATIONS; MEASURING INSTRUMENTS; METALS; MONITORING; NATIONAL ORGANIZATIONS; POPULATIONS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; ZERO POWER REACTORS
Optional Information
- Notes
- 16 refs