Published 2011 | Version v1
Journal article

Recalibration of indium foil for personnel screening in criticality accidents

  • 1. Japan Atomic Energy Agency, 4-33, Tokai-mura, Ibaraki-ken 319-1194 (Japan)

Description

At the Nuclear Fuel Cycle Engineering Laboratories of the Japan Atomic Energy Agency (JAEA), small pieces of indium foil incorporated into personal dosemeters have been used for personnel screening in criticality accidents. Irradiation tests of the badges were performed using the SILENE reactor to verify the calibration of the indium activation that had been made in the 1980's and to recalibrate them for simulated criticalities that would be the most likely to occur in the solution process line. In addition, Monte Carlo calculations of the indium activation using the badge model were also made to complement the spectral dependence. The results lead to a screening level of 15 kcpm being determined that corresponds to a total dose of 0.25 Gy, which is also applicable in posterior-anterior exposure. The recalibration based on the latest study will provide a sounder basis for the screening procedure in the event of a criticality accident. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncq342

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
144
Journal Issue
1-4
Journal Page Range
p. 575-579
ISSN
0144-8420

Conference

Title
European conference on individual monitoring of ionising radiation
Acronym
IM2010
Dates
8-12 Mar 2010
Place
Athens (Greece)

Optional Information

Notes
16 refs