Published 1979
| Version v1
Miscellaneous
Standing wave electron linac with a bridge circuit of power supply for defectoscopy and medicine
Creators
- 1. Moskovskij Inzhenerno-Fizicheskij Inst. (USSR)
Description
Experimental investigation of three electron linacs distinguished both with HF power supply and accelerating resonators was carried on to optimize biperiodical decelerating systems and HF power supply. Results of tests of three-sectional electron linac consisting of 3 accelerating buncher cells and 7 accelerating cells and 6 coupling cells of 85 cm accelerating section are given. 5.2 MeV mean energy at 10 mA beam current was generated during tests of the accelerator of 1.2 MW input power. Output beam radius did not exceed 2 mm. Prospects of u.age of standing wave electron linacs in national economy are shown
Additional details
Additional titles
- Original title (Russian)
- ЛУЭ со стоячей волной и мостовой схемой питания для дефектоскопии и медицины
Publishing Information
- Imprint Title
- Reports of 3. All-union conference on application of charged particles accelerators in national economy. V. 1
- Journal Page Range
- p. 186-195.
- Report number
- INIS-SU--62
Conference
- Title
- 3. All-union conference on application of charged particles accelerators in national economy.
- Dates
- 26 - 28 Jun 1979.
- Place
- Leningrad, USSR.
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 13665393
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ELECTRON BEAMS; FLOWSHEETS; LINEAR ACCELERATORS; MEV RANGE 01-10; MILLI AMP BEAM CURRENTS; PERFORMANCE TESTING; STANDING WAVES; USES
- Descriptors DEC
- ACCELERATORS; BEAM CURRENTS; BEAMS; CURRENTS; DIAGRAMS; ENERGY RANGE; INFORMATION; LEPTON BEAMS; MEV RANGE; PARTICLE BEAMS; TESTING
Optional Information
- Notes
- 4 refs.; 5 figs. Imprint:Doklady Tret'ego Vsesoyuznogo soveshchaniya po primeneniyu uskoritelej zaryazhennykh chastits v narodnom khozyajstve. Tom 1.