Published 1992 | Version v1
Journal article

Quality factors and ambient dose equivalent for neutrons based on the new ICRP recommendations

  • 1. Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

Description

Quality factors and fluence to ambient dose equivalent conversion coefficients for neutrons, based on the recent ICRP recommendation for the quality factor, were calculated for incident neutrons ranging from thermal neutrons to 20 MeV. The neutron quality factors are given in tabular form for the four elements H, C, N and O and for ICRU tissue substitute. An analytical function was fitted to the conversion coefficients. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
40
Journal Issue
2
Series
Radiat. Prot. Dosim.
Journal Page Range
85-89
ISSN
0144-8420
CODEN
RPDOD

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
23042887
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
DOSE EQUIVALENTS; ENERGY DEPENDENCE; NEUTRON DOSIMETRY; QUALITY FACTOR
Descriptors DEC
DOSIMETRY