Published March 15, 2017 | Version v1
Journal article

Electronically tuned sulfonamide-based probes with ultra-sensitivity for Ga3+ or Al3+ detection in aqueous solution

Description

Three electronically tuned fluorescent probes (1–3) were synthesized by conjugating a fluorescent unit to N,N-bis-(hydroxyethyl)ethylenediamine. Probe 1 bearing an electron-deficient naphthalenedimide unit did not give a fluorescence response to the presence of various metal ions including monovalent metal ions (Na+, K+, and Ag+), divalent metal ions (Ca2+, Cd2+, Co2+, Ni2+, Cu2+, Hg2+, Pb2+, and Zn2+) and trivalent metal ions (Al3+, Ga3+, Fe3+, and Cr3+) in an aqueous solution. By contrast, probes 2 and 3 possessing 1,8-naphthalimide and pyrene fluorophores, respectively, exhibited selective fluorescent "OFF-ON" behaviors as a result of Ga3+/Al3+ binding among the diverse metal ions, suggesting the importance of fluorophore electronic character with regard to metal ion sensing. The ethylenediamine analog of probe 3, corresponding to probe 4, was unable to yield a significant change in fluorescence intensity in the presence of any metal ions tested here, revealing the essential role of two hydroxyl groups for metal ion binding. A high association constant of Ka = 2.99 × 105 M−1 was obtained for probe 3 with Ga3+, with a limit of detection (LOD) of 10 nM. This LOD is the lowest value known for Ga3+ detection using chemical sensors. Along with an increase in aggregate sizes, PET suppression of probes upon metal ion binding was the primary contributor to the enhancement in fluorescence emission necessary for the sensitive detection of the target ions. The probe-metal ion complexes were fully characterized via TEM, FE-SEM, 1H NMR, fluorescence spectroscopy techniques and DFT calculations. - Highlights: • Three electronically tuned sulfonamide-based probes (probes 1, 2, and 3) were developed for metal ion-sensing. • Probes 2 and 3 exhibited AIE behavior with increasing water-content. • Probes 2 and 3 displayed a selective fluorescence "OFF-ON" behavior for Ga3+ detection with the LOD of 10 nM. • PET suppression and AIE jointly played a significant role for ultra-sensitive detection of Ga3+.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2016.12.032

Additional details

Identifiers

DOI
10.1016/j.aca.2016.12.032;
PII
S0003-2670(16)31506-9;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
958
Journal Page Range
p. 38-50
ISSN
0003-2670
CODEN
ACACAM

Optional Information

Copyright
Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.