Published 2009
| Version v1
Book
Standardization of tests of quality control with the aid of quality tools used in management systems of processes at the Sector of Nuclear Medicine of the University Hospital of Santa Maria, Rio Grande do Sul
- 1. Hospital Universitario de Santa Maria, RS (Brazil). Servico de Fisica Medica
- 2. Universidade Federal de Santa Maria (UFSM), RS (Brazil). Dept. de Estatistica. Programa de Pos-Graduacao em Engenharia de Producao
Description
This work tries to standardize the tests of quality control at the Sector of Nuclear Medicine at the University Hospital of Santa Maria, using tools of the quality used in systems of management of processes such as, PDCA, brainstorming, diagram of cause and effect (Ishikawa), 5W2H, verifying list and fluxogram. The tests of quality control refer to the scintillation camera (center of rotation, intrinsic uniformity, intrinsic spatial resolution and linearity, energy resolution for each radionuclide), to the dose calibrator (accuracy, reproducibility and linearity), to the Geiger-Mueller detector (reproducibility of the detector). (author)
Additional details
Additional titles
- Original title (Portuguese)
- Padronizacao de testes de controle de qualidade com o auxilio de ferramentas da qualidade utilizadas em sistemas de gerenciamento de processos, junto ao Setor de Medicina Nuclear do Hospital Universitario de Santa Maria, RS
Identifiers
Publishing Information
- Publisher
- ABFM
- Imprint Place
- Sao Paulo (Brazil)
- ISBN
- 978-85-85205-94-2
- Imprint Title
- Proceedings of the 14. Brazilian congress on medical physics; 4. Symposium on instrumentation and medical imaging
- Imprint Pagination
- [vp.]
- Journal Page Range
- [3 p.]
Conference
- Title
- 14. Brazilian congress on medical physics; 4. Symposium on instrumentation and medical imaging
- Original Conference Title
- 14. Congresso brasileiro de fisica medica
- Dates
- 8-12 Jul 2009
- Place
- Sao Paulo, SP (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 41113758
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DIAGNOSIS; NUCLEAR MEDICINE; QUALITY ASSURANCE; QUALITY CONTROL; RADIOISOTOPES; RADIOPHARMACEUTICALS; RELIABILITY; SCINTISCANNING; STANDARDIZATION; TRACER TECHNIQUES
- Descriptors DEC
- CONTROL; COUNTING TECHNIQUES; DIAGNOSTIC TECHNIQUES; DRUGS; ISOTOPE APPLICATIONS; ISOTOPES; LABELLED COMPOUNDS; MATERIALS; MEDICINE; RADIOACTIVE MATERIALS; RADIOISOTOPE SCANNING
Optional Information
- Notes
- Imprint:Anais do 14. Congresso brasileiro de fisica medica; 4. Simposio de instrumentacao e imagens medicas